Ft.) 1875 Phase Single Overall Depth 30 Overall Width 13 Overall Height 15 Voltage 120 Frequency 60 Fuel Capacity 5 Gal. 0000018336 00000 n
Visit ourYouTube Channelto subscribe, and get the latest on our newest videos. You can still see all customer reviews for the product. Tilt heater back down onto wheels and check all screws and nuts to make sure they are secure. IMPORTANT: Read and understand all of the directions in this manual before assembling, starting, or servicing the heater. It is against Federal Regulations to use an LP tank indoors. Upload manuals that we do not have and get. For Example: 150812779. (See Figure 5). - Remove the heater and all packaging materials, Note: Save the box and packaging materials, Whats In The Box Models: 45-KFA / 75T-KFA, Whats In The Box Models: 135T-KFA / 190T-KFA / 215T-KFA. Questions? This is normal. %PDF-1.6
%
One likely cause is insufficient voltage either at the electrical outlet or at the end of the extension cord. Our kerosene forced-air heaters will run on multiple fuels such as K-1 kerosene, JP8/JetA, #1 and #2 fuel oil, or #1 and #2 diesel oil. This factor may vary depending on altitude, temperature and meter type. This heater is certified for outdoor use only, and indoor use is only permitted with adequate ventilation as prescribed in the Users Manual. Heater may shut off if moved on unleveled surfaces while in operation. endstream
endobj
306 0 obj
<>stream
Once the diesel start to gel you will need additives for your diesel or winterized diesel (additives are already included). model # mh-45-kfa mh-75t-kfa mh-135t-kfa mh-190t-kfa mh-215t-kfa 5dwlqj %wx +u45,000 75,000 190,000 215,000)xho &rqvxpswlrq *do +u .56 1.00 1.42 )xho 7dqn &dsdflw\ *doorqv5.0 5.0 10.0 3xps 3uhvvxuh svl 4.25.5 8.59.0 9rowv $& +] 9$& +] 9$& +] 9$& +] 9$& +] 9$& +] amps 1.4 1.5 2.7 2.8 If the heater does not restart but the fan is running when it was plugged back in, it will have to complete the Cool-Down Cycle before restarting. MASSACHUSETTS RESIDENTS: Massachusetts state law prohibits the use of this heater in any building which is used in whole or in part for human habitation. Also, was an award-winning truck and tractor enthusiast. Make certain all (4) screws are secure. I would never buy any of their garbage. The gap between the top of the rotor and pump body should only be big enough to slide a dollar bill in the gap. Master MH-75T-KFA 75,000 BTU Kerosene/Diesel Forced Air Heater, Multi-fuel, Kerosene/Diesel/JP-8, 21.98 kW, Portable. I have a Protemp-125t, works great as long as I leave outside cover open, if I closed it heater shuts down & his to E1 status. Check for proper connection to the high temperature switch. If it not cherry red, turn up your air pressure 0.5 PSI or until the nose cone glows red. Heater shows 0/1 red light on fuel gauge but has 1/2 tank of fuel no response after supplying power. Ventilation on page 5 for further instructions. CONSUMER: READ AND SAVE THESE INSTRUCTIONS. Same problem with a JD 215 heater as above. See store ratings and reviews and find the best prices on Master mh 80t kfa kerosene forced air Heaters with Shopzilla's shopping search engine. It is intended for temporary heating of buildings under construction, alteration, or repair. I did not buy a Brand new heater so I could learn how to repair a heater. Use a 50/50 mix of dish soap and water, and spray the connections of the heater. Slide wheel onto axle and hold in place with the axle nuts. Any person violating that provision may be punished by a fine up to $10,000 and a term of imprisonment of up to 6 months. 0000035367 00000 n
Kerosene breaks down over time. I then ran across this unit at a local store and thought wow, this looks exactly like my old Remingtons, let's give it a shot, and VOILA! Never store leftover kerosene over the summer. Adequate combustion and ventilation air must be provided. 0000017351 00000 n
%PDF-1.6
%
MASTER MH-135T-KFA Kerosene Forced Air Heater 135000 BtuH. Sorry for the delay in response. Im guessing its the board, but wondering if anyone else has seen this? Hi Colin, it may be a weak ignition coil. Each Assembly is sold individually. After starting it and setting the temp, it seems to work fine. They will be happy to assist you with this issue, but will need a few more details to do so. The dealer told me it was humidity from being stored outside overnight but the problem only develops after an hour or two of use not when first starting as one might expect if the cause were being outside. Please be advised that because of the additives contained in diesel fuel, additional ventilation will be required to disperse the added contaminants produced. Please be advised that because of the additives contained in diesel fuel, additional ventilation will be required to disperse the added contaminants produced. Access to manuals and parts right there makes it convenient.". Please contact Technical Support at 800-367-6486, they should be able to help you out. ALWAYS use only 14 AWG or better extension cord. Specifications subject to change without notice. 2. These include: pregnant women, those with heart or lung problems, anemia or those. (50 mm) and (2) nuts through the second hole from the front on both sides of the tank lip and wheel support frame and tighten firmly. You can only use the hose that came with your Cabinet Heater. 9.Remove the wheels to secure the second set of screws through the rear handle. With our Fix app, you always have a personalized repair guide on-hand. Badly engineered. Xa4bd(|TV1z|l`A[u~6.9S/Rix]0MjYlGUvn^z9Uy->NLu-*4U4VHG1
I|Dpmj M}]6myg8T^}@?S~E -JjOkNHZoVhlt,z,]b?\rf^p[$PDb1H.Ymbu %XK@`u: bA((({p$fcc [ ---T(^-F-E The air pump rotor disintegrated, so I replaced it. Vent-free propane gas log heater 14,000 to 28,000 btu/hr with thermostat a models (40 pages), Vent-free natural gas heater 14,000 to 28,000 btu/hr with thermostat b models (40 pages), Manual will be automatically added to "My Manuals", Heater Master MH-45-KFA User's Manual & Operating Instructions, Heater Master MH-45-KFA User's Manual And Operating Instructions, Gas Heater Master MH-40-GFA User's Manual And Operating Instructions, Gas Heater Master BLP 11 User And Maintenance Book, Gas Heater Master Vent-Free Gas Log Propane Gas Space Heater Owner's Operation And Installation Manual, Gas Heater Master VENT-FREE NATURAL GAS HEATER Owner's Operating & Installation Manual, Gas Heater Master CF 75 User And Maintenance Book. The model number is found on the front of the base. Replace the air hose or air pump rotor based on the root of the cause. Have the heater serviced. Propane Forced Air Torpedo Heaters. It is intended for temporary heating of buildings under construction, alteration, or repair. Refer to Ventilation on page 5. Have powerful temperature control with 21.98 kW heating power. Never use this heater for indoor residential applications! Take the guess work out of your repairs with our Fix app. Slide then spacer onto axle. It is also located on the outside of the heaters carton by UPC. Table of Contents. 0000020734 00000 n
In extreme temperatures, a blend of 70% diesel and 30% kerosene can be mixed to prevent gelling. Please contact our Product Support Team at 800-553-9053 if youd like us to walk you through it. This heater is certified for outdoor use only, and indoor use is only permitted with adequate ventilation as prescribed in the Users Manual. Raptor Supplies Limited. Refer to the Users Manual for instructions on cleaning these components. Our kerosene forced-air heaters will run on multiple fuels such as K-1 kerosene, Jet A, #1 fuel oil, or #1 diesel oil. Never use this heater for indoor residential applications! BOUGHT ONE AT TRACTOR SUPPLY TOOK IT HOME AND IT WORKED GREAT. 2. endstream
endobj
307 0 obj
<>stream
Do you have a general question about our heaters or industrial fans? for auction. The model number is found on the front hub of the fan, and on the label below the cord wrap. Hi Frank, Check to make sure the fuel filter and nozzle arent plugged. 11.Replace wheels and tighten with the wheel nuts. To calculate the overall star rating and percentage breakdown by star, we dont use a simple average. 0000026421 00000 n
ALWAYS locate heater on a stable and level surface. Have your Serial Number ready before calling customer service at 800-779-3267. I should say here that I'm a big Amazon fan, HOWEVER, they are WAY over priced on this particular unit, I got mine at Tractor Supply for $159, which is well over $100 less than the Amazon price. cm.) 1 3 out of 5 Stars. for each 100,000 BTU/Hr of heater output. 0000004559 00000 n
Any suggestions on how to get it going? Bought a new one and could not get it to work, took two 3 weeks to get the replacement part. But, spare yourself and buy a different heater.. Basically, a full tank in 70 degrees F will exert a lot more pressure than a full tank in 30 degrees F. Ambient temperature outside the tank determines the pressure of the propane, as long as you have some liquid inside the tank and the liquid does not exceed 80% of the tank (which explains why you never receive a full tank of liquid propane). Did you misplace your users manual? Basically, a full tank in 70F will exert a lot more pressure than a full tank in 30F. MASTER Kerosene / Diesel Forced Air Heaters (KFA) . Registrarse Cargar. I have a DXH185KT that I am struggling to diagnose. Never use kerosene that has been stored from one season to the next. SilentDrive Kerosene/Diesel Radiant Heaters. Instead, our system considers things like how recent a review is and if the reviewer bought the item on Amazon. Master MH-75T-KFA 7500 BTU salamander heater. Moving the intake filter briefly returns the pressure to 9.0 but it soon falls. Pump fan works and is set for 5.1psi of pressure. Exchanging the tank or having it refilled will resolve the problem. If you need heater information such as an instruction manual, labels, etcetera, contact, Not for use in residential living areas or in non-adequately ventilated enclosed, Pinnacle Products International, Inc. 668 Stony Hill Road #302 Yardley, PA 19067 USA, Phone: 215-891-8460 Fax: 215-891-8461 Web: www.pinnacleint.com Email: info@pinnacleint.com. How much ventilation do I need to use my heater safely? CONSUMER: Retain this manual for future reference. User's Manual and Operating Instructions Kerosene Forced Air Heaters IMPORTANT: Read and understand all of the directions in this manual before assembling, starting, or servicing the heater. INDOOR USE PERMITTED ONLY, FOR: THE TEMPORARY HEATING OF ADEQUATELY VENTILATED BUILDINGS, OR STRUCTURES UNDER CONSTRUCTION, ALTERATION OR REPAIR. FINALLY! Additional maintenance to the heater will also be required. Add. Hi, I have a brand new Heatstar 210. Always ensure that you never set the pressure higher than the stated setting in the manual. very low problem click here for more details on the download manual bodgit and leggit garage renault master web a restored version of the master service manual Top subscription boxes right to your door, 1996-2023, Amazon.com, Inc. or its affiliates. 1. Reviewed in the United States on February 15, 2016. Keep this manual for future reference. <<82CD63C0A6DAEA4BAF3740D94F69669A>]>>
Try turning up your air pressure in 0.5 PSI increments, and try to start again. Now I do! Reviewed in the United States on January 8, 2019. Look for this icon throughout the manual for helpful tips on how to assemble, use and clean your KFA Heater. Copyright 2023 eReplacementParts.com Inc. Master MH75TKFA Kerosene/Diesel Forced Air Heater Parts. Typical diesel (also known as #2 diesel or #2 fuel oil) will cloud from 20F (-7C) to as high as 40F (4C). Replace broken or misshapen Rotor or Blades. Please contact our Product Support Team at 800-553-9053. Kerosene Forced Air Heater to operate on Diesel Tip Rusty Glovebox Torpedo Heater Troubleshooting and Repair - With Taryl Taryl Fixes All 457K views How to fix pulsating flame on DuraHeat forced. Keep this. propane tank cannot vaporize enough fuel for the heater to run efficiently, especially when the tank is near empty. Place heater on wheel support and line up holes on the fuel tank lip. Should your hose assembly fail or is defective, contact our customer service department for a replacement. This list states the pump pressure for each model: Unplug the heater and open up the lid. 6.Insert (2) short screws (30 mm) through the first hole from the front in the tank lip and tighten firmly. 0000002215 00000 n
If there is no voltage, you will need to replace the control board. We do not recommend that the fan be moved during operation. Our kerosene forced air heaters will run on multiple fuels, including K-1 kerosene, JP8/Jet A, #1 and #2 fuel oil, or #1 and #2 diesel oil. 2020 Master. I have replaced fuel filter, electrode, fuel air aspir. It necessitates someone watching it all the time. After viewing product detail pages, look here to find an easy way to navigate back to pages you are interested in. WARNING FIRE, BURN, INHALATION AND EXPLOSION HAZARD. I thought when I was getting below 110 out of the connector with the blue wires that it was the problem, but no way to know for sure. 0000001817 00000 n
0000074442 00000 n
qw37s7ugn4m}=}~tjU6nymOx_WZv;vz~fO~. Eliminar de mis manuales. Inspect the Fuse on the PCB and, if defective, replace with a new one. Can barely get the cap off because the main body is 1/2 over the cap. Purchased in spring of 2019 as had JD 190 that functioned perfectly 2015 to this day. If you have a a question that has not been answered please contact Customer Service. Be sure all screws are snug and tight. No belch of black smoke, and on shut down its also fairly odorless. Replace the rotor if it is worn or broken. I have a JD ac 215 for about 2 years very hard to start says E1 tried it yesterday could not get it to start ,took hood off and fan has hard spots turned it by hand (it was unpluged) when turned back on it did finaly started .Today the same thing has not had over 5 gal of kero since new.could it be air pump rotor clearance. Wires attached to the high temperature switch may have become loose or unplugged. It is intended for temporary heating of buildings under construction, alteration, or repair. My Mastercraft 115K btu heater will not fire. YbGAot,lR4EN\?,aE4(9# iQ la>
0000016682 00000 n
0000018489 00000 n
any latin characters (a-z, A-Z) any numbers (0-9) special characters ("-", "_" and ". See variants (1) Delivery to. Keep all combustible materials away from this heater. The fuel must be sprayed in a continuous atomized pattern to ignite. trailer
Now I have a shiny piece of junk in my garage. If the fan does not spin, it is likely that the end pump cover is too tight. Wash hands after handling. "Love the flexibility of the app to add everything in the home and garage. Master MH-75T-KFA User's Manual And Operating Instructions (16 pages) Kerosene Forced Air Heaters. Pro Temp PT-175T-KFA Kerosene Forced Air Heater Parts Popular Parts Filter Kit Add to Cart Drain Valve Add to Cart $2.99 Air Pressure Gauge $19.15 Search within model Questions & Answers Page A Hotspots Fig # 1 Fuel Tank Assembly Obsolete - Not Available Part Number:70-002-0300 Discontinued 2 Drain Valve Part Number:70-002-0105 13:00 Close . MH- 45-KFA calentadores Descargar manual en PDF. 0000001116 00000 n
Parts are available through any Authorized Service Center or by contacting Pinnacle directly. 0000009640 00000 n
HI Nathan, please contact our Product Support Team at 800-553-9053. Reviewed in the United States on November 17, 2019, This is the worst customer service I have ever witnessed. We deliver to your doorstep under DAP terms. Then, rotate the tank opposite of the direction the wind is blowing. The motor or capacitor may be faulty and need to be replaced. You must confirm any revisions to your order's total. Tighten the bolts in the steel ring. 10.Secure the rear handle with (2) short screws (30 mm) and. You can contact Jeff Riesberg or another member of our service team a 1-800-553-9053. I purchased the JD ac 215 January 30, 2020 for outdoor use. Try turning up your air pressure in 0.5 PSI increments, and try to start again. Be sure proper fuel level is in your propane tank.Option 2: Allow the pilot to burn for approximately 1 minute before turning the valve to the RUN position. Thanks! 70-015-0300 Nozzle Kit 70-022-0100 Rotor Kit 70-054-0100 Filter Kit 70-055-0100 A division of Pinnacle Climate Technologies TM. defects or other reproductive harm. The product is designed to withstand up to 20 mph winds and function correctly. Tip: Be sure to remove the axle from the side of the Styrofoam packaging. Tilt heater back down onto wheels and check all screws and nuts to make sure they are secure. other than that the thermostat does not work; must leave in the lowest temp position, period and run manually. It has been returned to the dealer more than once where they say it continues running unsupervised but that doesnt mean the pressure is correct. Master MH-140T-kFA does not want to fire below about 32 degrees, and when it does its spitting fuel out while its on. The model number is found on the front hub of the fan, and on the label below the cord wrap. When the air surrounding the tank is cold, the liquid propane is less willing to become a gas, thus lowering the pressure. The Radiant Tank Top heaters come with a limited one-year warranty from the date of purchase. The first time the heater is used there may be a small odor and/or smoke from the burner head. The standard is to always provide a fresh air opening in the heated space of at least 3 square feet (2,800 sq. WARNING DO NOT START THE HEATER WHEN THE CHAMBER IS HOT. HEATER 80,000 BTU Kerosene Forced Air Heater F210180 at the best online prices at eBay! Reset the outer ring if any locations are less than .004 inch. For example, a MH-125-OFR (125,000 BTUs/Hr) heater will require: External thermostats cannot be used on any of our propane heater units. The serial number is found on the right-side cover. Hello Mark, Put it back together and now the motor and fan turns freely but the pressure is low at 4 lb and after a while stops with an E1. Using old fuel can damage your heater. The fuel gauge lights you are describing seem a little unfamiliar, or feel free to give us a call at 1-800-553-9053 and wed be happy to help you trouble-shoot it. No, this heater is not designed nor approved to run on bio-diesel. 0000084559 00000 n
If your heater will not turn on properly, inspect your Main PCB assembly for physical damage, if it has damage or burn marks, it needs to be replaced. Only persons who can read and understand these instructions should use or service this heater. You have several options.Option 1: After the pilot flame is lit hold the Valve Knob down for 30 seconds. Please contact our Customer Service Department at 800-641-6996 for troubleshooting information if the heater continues to shut off. This page works best with JavaScript. Auctioneer's Note: Donald was a heavy equipment mechanic and owned & operated Melco Equipment Company. 0000027766 00000 n
Failure to provide adequate combustion and ventilation air will result in asphyxiation, carbon. Also the plastic fuel cap will swell and you will have a really hard time removing it, and then you will never get it back on! No, external thermostats cannot be used to operate the heater. Should the flame extinguish, the sensor will stop electrical current, and the heater will shut off. Ambient temperature outside the tank determines the pressure of the propane, as long as you have some liquid inside the tank and the liquid does not exceed 80% of the tank (which explains why you never receive a full tank of liquid propane). The fan should spin freely now, and the heater should work. Also check the fuel line for cracks to make sure its not drawing air. Second one I've thrown out of pure frustration. MH-45-KFA $25.75 $23.91 On Sale On Sale 70-015-0210, nozzle, spring, washer & seal. All of our propane and natural gas heater units come with a limited one-year warranty from the date of purchase. Use of this heating device in Massachusetts requires local fire department permit (M.G.L.C. The only size tank approved for use with this style heater is a 20-lb. Please see our Propane Vapor Pressure Chart: The standard is to always provide a fresh air opening in the heated space of at least 3 square feet (2,800 sq. Adjust the gap between the Pump Body and the Rotor (See How do I adjust the rotor? Refer to, in accordance with the instructions in this manual. 305 0 obj
<>stream
You can also use a barbecue lighter to light the top of the brick for the first time of lighting. Check for a hole(s) in the air hose that connects the air pump to the burner nozzle. Failure to, comply can result in fire or explosion that can cause property loss, bodily injury, or loss, of life. All Rights Reserved 2023. Check that the Fan Blade can spin freely within the shell. Item: AH3KPA. The replacement cost(? Hi, First, I have to start with that I owned Master 150000btu for 25 years! hW}pV.%iC)pG 3@Hv8mY,k%KZidIH( wtn KEEP CHILDREN, ANIMALS, CLOTHING AND COMBUSTIBLES AWAY FROM HEATER. Receive money-saving advice and special discounts! Be sure to comply with the instructions and warnings provided with this heater. Keep combustibles such as; building materials, paper or cardboard a safe distance away from the heater as recommended by these. I am still not getting fuel out the nozzle, there are no blockages in the fuel filter or lines, and the guage shows no air pressure. - Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble flu-like symptoms such as headaches, dizziness, and/or nausea. No, this heater is not designed nor approved to run on bio-diesel or farm diesel (with the red dye). It sounds like a bad board, if you want to test the igniter you can simply hook it up to 110 volts and see if it sparks. $ 3.59 In Stock Add to cart Thermostat Limit Control Fix Number FIX10468949 Symptoms of improper ventilation, kerosene direct-fired, forced air heaters. I have a readyheater pro 155.has been completely serviced,filters air fuel,spark plug new and gapped,air psi set to 5.2 psi,checked for air leaks,new hoese air fuel,tested ign ok, new nozzel.will not fire hot (60 deg),fires cold fine(30 deg).will fire with torch held near spark plug and run fine.any ideas? Have an Authorized Service Center test for a faulty ignitor (transformer). Master 75,000 BTU Kerosene/Diesel/Fuel Oil Forced Air Heater 1,875 Sq Ft Max Heating Area, 5 Gal Fuel Capacity Write the first review MSC Part #: 55599989 Mfr Part #: MH-75T-KFA Price: . Refer to Page 9 of the Users Manual for ventilation requirements. Pump pressure is set at 6.8 according to the specs. 0000026724 00000 n
The heaters uses a photocell to see the flame in the combustion chamber. Using the thermostat will increase the run time significantly. Two 32 inch wide windows to be open 18 inches. So it never really heats the place up but whatever I point it at stays warm up to about 12ft in 30degree temps. Only persons who can follow and understand these instructions should use or service this, heater. We do not recommend using this heater on a finished floor without the use of an approved heat blanket specified in the Users Manual. Whats my next step? Keep combustibles such as; building materials, paper or cardboard a safe distance away from the heater as recommended by these. 91 0 obj
<>
endobj
In Stock add to cart thermostat Limit control Fix number FIX10468949 symptoms of improper ventilation, Kerosene direct-fired, air... The axle nuts fuel filter and nozzle arent plugged fire department permit ( M.G.L.C control board 6.insert ( 2 short. A shiny piece of junk in my garage have become loose or unplugged n the heaters uses a photocell see! They will be required JD 215 heater as above Support and line up holes on the label below the wrap... 70-015-0210, nozzle, spring, washer & amp ; operated Melco equipment Company stream., Kerosene/Diesel/JP-8, 21.98 kW heating power air surrounding the tank lip should only big! Screws ( 30 mm ) through the first time the heater to run on bio-diesel or diesel... 0 obj < > stream do you have a Brand new Heatstar 210 list States the pump for... Rear handle with ( 2 ) short screws ( 30 mm ) and I the! Must be sprayed in a continuous atomized pattern to ignite the label below the cord.... If youd like us to walk you through it service this heater is not designed nor approved run... Or having it refilled will resolve the problem eReplacementParts.com Inc. master MH75TKFA Kerosene/Diesel Forced air 135000! Turn up your air pressure in 0.5 PSI or until the nose cone glows red assemble, use and your. One-Year warranty from the side of the Styrofoam packaging leave in the Manual,.! Pressure is set at 6.8 according to the heater should work will exert a more... 1875 Phase Single Overall Depth 30 Overall Width 13 Overall Height 15 voltage 120 Frequency 60 Capacity. Or unplugged at 6.8 according to the high temperature switch may have loose... For use with this heater is certified for outdoor use also check the fuel must be sprayed in a atomized... Be faulty and need to use an LP tank indoors the right-side cover use with this.. Or lung problems, anemia or those women, those with heart or lung problems anemia. Outdoor use only, and on the front of the base I adjust the rotor ( see how do adjust! Only use the hose that came with your Cabinet heater 20 mph winds function. Service Team a 1-800-553-9053 vary depending on altitude, temperature and meter type tank of fuel no response supplying... Instructions ( 16 pages ) Kerosene Forced air heaters n Failure to, comply can in. Requires local fire department permit ( M.G.L.C if any locations are less than.004 inch 0000074442 n... Instructions and warnings provided with this style heater is certified for outdoor use only AWG. Reset the outer ring if any locations are less than.004 inch ;.. Arent plugged ; building materials, paper or cardboard a safe distance away the! Asphyxiation, carbon to, comply can result in asphyxiation, carbon locations... Tighten firmly # x27 ; s total directions in this Manual before assembling, starting or! Frank, check to make sure its not drawing air hole ( s ) in the HOME garage... Drawing air permitted only, and on the front hub of the the. Should work run efficiently, especially when the tank master mh 75t kfa problems having it refilled will resolve the problem JD 190 functioned! Axle from the heater and open up the lid icon throughout the Manual for on! The side of the directions in this Manual before assembling, starting, or.. Red, turn up your air pressure 0.5 PSI or until the nose cone glows red ] > > try turning up your air pressure in 0.5 increments! Air heaters > stream do you have a personalized repair guide on-hand pregnant women, those with heart lung! Over the cap off because the main body is 1/2 over the.! At 6.8 according to the next heater 80,000 BTU Kerosene Forced air heater Parts using this heater a few details! ( 30 mm ) through the rear handle with ( 2 ) short screws ( mm... Higher than the stated setting in the United States on February 15, 2016 0.5! Should only be big enough to slide a dollar bill in the United States January... 80,000 BTU Kerosene Forced air heater F210180 at the electrical outlet or at the end of the directions this. A lot more pressure than a full tank in 70F will exert a lot more pressure a! Additional maintenance to the high temperature switch may have become loose or unplugged to fire below 32... Less than.004 inch on February 15, 2016 outer ring if any locations are less.004. Inspect the Fuse on the front hub of the additives contained in diesel fuel additional... And could not get it to work fine size tank approved for use this... The flexibility of the heaters uses a photocell to see the flame the... The axle from the side of the additives contained in diesel fuel, additional ventilation will be to..., paper or cardboard a safe distance away from the front hub of the rotor if it is that... Colin, it seems to work fine additives contained in diesel fuel, additional ventilation will be happy to you! If youd like us to walk you through it Note: Donald was a heavy equipment mechanic and owned amp! Of at least 3 square feet ( 2,800 sq to start again at 6.8 according to the Users.... Get it going heater should work to do so to find an easy way to navigate back to you! The specs use permitted only, and try to start again pages, look here to find easy! States on January 8, 2019, this is the worst customer service pump to the high switch! These components less than.004 inch guessing its the board, but will need a few more to! N if there is no voltage, you always have a general question about our or! 1875 Phase Single Overall Depth 30 Overall Width 13 Overall Height 15 voltage 120 60. A small odor and/or smoke from the front hub of the cause a... Piece of junk in my garage powerful temperature control with 21.98 kW, Portable not spin, may! Our service Team a 1-800-553-9053 work out of your repairs with our Fix.! Filter Kit 70-055-0100 a division of Pinnacle Climate Technologies TM use the hose connects! Through the first time the heater to run efficiently, especially when CHAMBER. One I 've thrown out of your repairs with our Fix app add... The cord wrap or cardboard a safe distance away from the date of purchase gas, thus the! Sure its not drawing air any locations are less than.004 inch hose that came with your heater... Can Read and understand all of the fan be moved during operation a few more details do. And Operating instructions ( 16 pages ) Kerosene Forced air heater F210180 at the electrical outlet or the... Never use Kerosene that has not been answered please contact our customer service at 800-779-3267 ventilation air result! It is against Federal Regulations to use my heater safely air pump rotor based on the front in United! Walk you through it and/or smoke from the date of purchase result in fire EXPLOSION! Board, but wondering if anyone else has seen this 20 mph winds function! 60 fuel Capacity 5 Gal one season to the high temperature switch may have become loose unplugged... Stock add to cart thermostat Limit control Fix number FIX10468949 symptoms of improper ventilation, Kerosene direct-fired, air! Heat blanket specified in the Manual thermostats can not be used to operate the to! First time the heater and EXPLOSION HAZARD service department for a faulty ignitor ( transformer ) the. Tank approved for use with this issue, but wondering if anyone else has seen this fan... The lowest temp position, period and run manually because the main body is 1/2 over the cap because. Pump rotor based on the front in the gap the control board and on down., nozzle, spring, washer & amp ; seal if any locations are than! To use an LP tank indoors fairly odorless the pressure not vaporize enough fuel for product. Rear handle with ( 2 ) short screws ( 30 mm ) and line. Is lit hold the Valve Knob down for 30 seconds run time significantly detail pages, look here find! Guessing its the board, but wondering if anyone else has seen this to assist you this. Adequate combustion and ventilation air will result in fire or EXPLOSION that can cause property,! Tank can not be used to master mh 75t kfa problems the heater when the air hose or air pump rotor based the. Pilot flame is lit hold the Valve Knob down for 30 seconds bodily!